Configuration/programming
2.6 Export/import project
TM15 / TM17 High Feature Operating Manual
Commissioning Manual, 05/2009
39
2.6 Export/import project
A consistent project, which uses TM15 or TM17 High Feature Modules, can be consistently
exported and reimported via Project Export/Import.
If only the SIMOTION CPU is exported, the message frame configuration for TM1x is not
exported with it. Thus, the current message frame configuration is not changed as a result of
an import to a CPU.
If only the SINAMICS drive unit is exported, the message frame configuration for TM1x is not
exported with it. The TM1x configuration must be completely deleted after an import.
Select the SIMOTION CPU in the project tree and right-click to open the context menu.
Delete the configuration with the menu Fast IO --> Delete Configuration.
Regenerate the data. Open the Configuration under SINAMICS_Integrated in the project
tree. The data is regenerated by individually aligning each slave using the Transfer to HW
Config button.

Table of Contents

Other manuals for Siemens SIMOTION TM15

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTION TM15 and is the answer not in the manual?

Siemens SIMOTION TM15 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTION TM15
CategoryTouch terminals
LanguageEnglish

Related product manuals