Loading...
Components in the same control cabinet, PP-switching outputs
You must use a two-channel cable connection when connecting PM-switching fail-safe digital
outputs to a fail-safe digital input.
6DIHW\IXQFWLRQ
6DIHW\IXQFWLRQ
352),1(76DIHW\
9'&
0
(0)'2'&9$
352),VDIH
)',
)',
',
',
',
',
',&20
',&20
6,1$0,&6*
&8(
(76
)&38
30(
DI COM1 Reference potential for digital inputs DI 0 and DI 2
DI COM2 Reference potential for digital inputs DI 1 and DI 3
Figure 4-23 Connecting PM switching ET 200S outputs using a SINAMICS G120 with CU240E‑2 as
example
6DIHW\IXQFWLRQ
6DIHW\IXQFWLRQ
352),1(76DIHW\
9'&
0
)'4෪9'&$30+)
)',
)',
',
',
',
',
',&20
',&20
6,1$0,&6*
&8(
(763
)&38

/
0
1)
The wiring of the ET 200SP shows as example, the supply of a new potential group when using a
bright base unit.
DI COM1 Reference potential for digital inputs DI 0 and DI 2
DI COM2 Reference potential for digital inputs DI 1 and DI 3
Figure 4-24 Connecting PM-switching ET 200SP outputs using a SINAMICS G120 with CU240E‑2 as
example
Installing
4.4 Controlling via a fail-safe digital input