Advanced commissioning
7.6 Basic positioner and position control
Converter with control units CU250D-2
Operating Instructions, 04/2015, FW V4.7.3, A5E34261542B AB
171
Correcting backlash
Precondition
You have selected the "Mechanical system" screen.
To correct the measured backlash, set the following:
● If the axis has not traveled far enough, then set a positive backlash.
● If the axis has traveled too far, then set a negative backlash.
You have corrected the backlash.