Adapt fieldbus configuration
6.2 PROFIdrive profile for PROFIBUS and PROFINET
Converter with control units CU250D-2
96 Operating Instructions, 04/2015, FW V4.7.3, A5E34261542B AB
Control and status word 1 for the positioner
Positioning control word 1 (POS_STW1)
Table 6- 8 POS_STW1 and interconnection in the converter
Traversing block selection, bit 0
Selecting the traversing block
Traversing block selection, bit 1
Traversing block selection, bit 2
3 Traversing block selection, bit 3 p2628 = r2091.3
8 0 = Relative positioning is selected
The converter interprets the position setpoint as the
position setpoint relative to the start position.
p2648 = r2091.8
1 = Absolute positioning is selected The converter interprets the position setpoint as
absolute position setpoint relative to machine zero
9 01 = Absolute positioning for rotary
axis in the positive direction
Selection of the positioning type for a rotary axis. p2651 = r2091.9
10 10 = Absolute positioning for rotary
axes in negative direction
p2652 = r2091.10
00, 11 = Absolute positioning for a
rotary axis through the shortest
12 1 = Continuous acceptance The converter accepts position setpoint changes
p2649 = r2091.12
0 = MDI block change with control
word 1, bit 6
The converter accepts a changed position setpoint
with the signal change 0 → 1 of control word 1, bit
6. See also Section: Control and status word 1
14 1 = Select Set up Toggling the axis operating mode between "Set up"
and "Positioning", see also Section: Direct setpoint
input (MDI) (Page 220).
p2653 = r2091.14
0 = Select positioning
15
The converter receives its position setpoint from an
external control.
p2647 = r2091.15