Installation
4.2 Electrical Installation
Converter with control units CU250D-2
Operating Instructions, 04/2015, FW V4.7.3, A5E34261542B AB
53
Connecting the PROFINET interface
Industrial Ethernet Cables and cable length
Listed in the table below are the recommended Ethernet cables.
Table 4- 14 Recommended PROFINET cables
Industrial Ethernet FC TP Standard Cable GP 2 x 2
Industrial Ethernet FC TP Flexible Cable GP 2 x 2 85 m (278 ft) 6XV1870–2B
Industrial Ethernet FC Trailing Cable GP 2 x 2
Industrial Ethernet FC Trailing Cable 2 x 2
Industrial Ethernet FC Marine Cable 2 x 2
The screen of the PROFINET cable must be connected with the protective earth. The solid
copper core must not be scored when the insulation is removed from the core ends.
Encoders examples
Examples
The following SSI encoders have been commissioned successfully in several applications
with the CU250D-2:
Table 4- 15 SSI encoders
SIEMENS 6FX2001-5xS12 Singleturn encoder p0400 = 3081 ---
SIEMENS 1XP80X4-20 /
Multiturn encoder p0400 = 3082
T&R CEW-58, CEV-58,
CEH-58, CEW-65;
Programmable en-
coder
p0400 = 9999.
Set the encoder
data manually.
We can not guar-
antee the func-
tion of these
encoders in any
circumstance.
SICK / Steg-
mann
DME4000 Laser distance
measuring unit, pro-