Advanced commissioning
7.6 Basic positioner and position control
Converter with control units CU250D-2
186 Operating Instructions, 04/2015, FW V4.7.3, A5E34261542B AB
Flying referencing
The converter corrects its position actual value while traversing and reduces errors, e.g.
caused by wheel slip or a gear ratio that has not been precisely set.
Example: A pallet on a roller conveyor must be stopped at a specific position. However, the
exact position of the pallet on the conveyor is only known when a sensor is passed.
Figure 7-33 Positioning an item to be transported on a roller conveyor
Set the reference point and adjust the absolute encoder
The converter takes the reference point coordinate as the new axis position.