EasyManua.ls Logo

Siemens SINAMICS S 1PH7 - Motor Components (Options); 5.1 Thermal Motor Protection

Siemens SINAMICS S 1PH7
244 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1PH7 induction motors (Machine tools)
Configuration Manual, (APH7W), 04/2009, 6SN1197-0AD72-0BP0
189
Motor components (options)
5
5.1 5.1 Thermal motor protection
A temperature-dependent resistor is integrated as temperature sensor to monitor the motor
temperature.
The sensor is evaluated in the converter whose closed-loop control takes into account the
temperature characteristic of the motor winding. When a fault occurs, an appropriate
message is output at the converter. When the motor temperature increases, a message
"Alarm motor overtemperature" is output; this must be externally evaluated. If this message
is ignored, the converter shuts down with the appropriate fault message after a preset time
period or when the motor limiting temperature or the shutdown temperature is exceeded.
WARNING
Sufficient protection is no longer provided for thermally critical load situations, e.g. for a
high overload condition at motor standstill. In this case, other protective measures must be
provided, e.g. a thermal overcurrent relay. The "thermal motor model i2t monitoring"
function must be activated in the converter.
The temperature sensor is part of a SELV circuit, which can be destroyed if a high voltage is
applied. The temperature sensor is designed so that the DIN/EN requirement for "protective
separation" is fulfilled.

Table of Contents