Loading...
Mechanical properties of the motors
3.3 Bearing version
1PH7 induction motors (Machine tools)
58 Configuration Manual, (APH7W), 04/2009, 6SN1197-0AD72-0BP0
Table 3- 10 Regreasing intervals
Shaft
height
Bearing type/
drive output type
Bearing-
type
motor
side
Bearing
designa-
tion
Re-lubricating
intervals in
operating
hours
[h]
Quantity of
grease for
each
re-lubrication
operation
1)
[g]
Grease
chamber
2)
[g]
Possible
number of re-
lubricating
intervals
3)
180 Deep-groove ball
bearings coupling
output
DE
NDE
6214 C3
6214 C3
8000 15 80 5
180 Cylindrical roller
bearings
belt coupling,
increased radial
forces
DE
NDE
NU2214E
6214 C3
6000 20 80 4
225 Deep-groove ball
bearings
coupling output
DE
NDE
6216 C3
6216 C3
8000 25 160 6
225 Cylindrical roller
bearings
belt coupling,
increased radial
forces
DE
NDE
NU2216E
6216 C3
6000 40 160 4
1)
Grease quantity for re-lubrication, normal conditions.
2)
Quantity of grease that can be injected into the grease chamber when precisely maintaining the quantity of grease for
each re-lubrication interval.
3)
Calculated number of re-lubricating intervals; the bearing lifetime is specified according to statistical perspectives in
accordance with the L
10h
definition.
NOTICE
Unfavorable factors such as the effects of mounting/installation, speed or mechanical loads
require that the re-lubricating intervals are appropriately adapted. Situations such as these
require special consideration or must be be calculated - and must be engineered according
to the limitations and constraints together with the responsible motor plant.