System Overview
Overview
1-23
E Siemens AG, 2004. All rights reserved
SINAMICS S120 Installation and Start-Up Manual, 12/04 Edition
systemübersicht_2.vsd
Network
DRIVE –CLiQ
Line reactor
Line filter
24 V DC
SITOP
Motors with
Integrated
Drive –CLiQ –
interface
Motors
without encoder
Motors with
Standard –
encoder
Sensor
Module
Terminal
Modules
Network
DRIVE –CLiQ
Interface
Module
Motors with
Integrated
Drive –CLiQ –
interface
Motors
without encoder
Motors with
Standard –
encoder
1 Control unit
2 Smart or
Active Line Module
3 Single Motor Modules
4 Double Motor Modules
1
234
1
2333
Sensor
Module
PC –tools
SIZER and
STARTER
Option
Boards
Terminal
Modules
Option
Boards
Power cable
Signal cable
DRIVE –CLiQ
Booksize Chassis
Fig. 1-4 Detection of the electronic rating plate via DRIVE-CLiQ on SINAMICSS120
In addition to the technical data, the type plate includes logistical data (manufac-
turer ID, order number, and globally unique ID). Since this data can be called up
electronically on site or remotely, all the components used in a machine can always
be individually identified, which helps simplify servicing.