Basic Information about the Drive System
BICO technology: interconnection of signals
7-244
E Siemens AG, 2004. All rights reserved
SINAMICS S120 Installation and Start-Up Manual, 12/04 Edition
Scaling for object A_Inf
Table 7-7 Scaling for object A_Inf
Size
Scaling parameters Default at first commissioning
Reference frequency 100 % = p2000 p2000 = p0211
Reference voltage 100 % = p2001 p2001 = r0206/r0207
Reference current 100 % = p2002 p2002 = p0207
Reference power 100 % = r2004 r2004 = p0206
Reference control factor 100 % = Maximum output voltage
without overload
-
Reference temperature 100 % = 100°C -
Reference electrical angle 100 % = 90° -
Scaling for object B_Inf
Table 7-8 Scaling for object B_Inf
Size
Scaling parameters Default at first commissioning
Reference frequency 100 % = p2000 p2000 = 50
Reference voltage 100 % = p2001 p2001 = r0206/r0207
Reference current 100 % = p2002 p2002 = p0207
Reference power 100 % = r2004 r2004 = p0206
Reference temperature 100 % = 100°C -
Reference electrical angle 100 % = 90° -