EasyManua.ls Logo

Siemens SINAMICS S120 - Page 270

Siemens SINAMICS S120
294 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Basic Information about the Drive System
Firmware upgrade
7-270
E Siemens AG, 2004. All rights reserved
SINAMICS S120 Installation and Start-Up Manual, 12/04 Edition
Component firmware upgrade sequence via parameters:
S Enter the component number in parameter p7828
p0121 Power Module component number
p0141 Component number encoder interface (SMC)
p0151 Terminal Module component number
S Start the firmware upgrade from the CompactFlash Card by entering a “1” in
parameter p7829.
Upgrade successful --> parameter changes back to “0”
Error --> a negative error code is output
S Perform a reset (e.g. POWER ON) to activate the firmware
S The firmware version can be checked in the following parameters:
r0128 Power Module firmware version
r0148 Voltage sensing module, firmware version
r0158 Terminal Module firmware version
Note
If the upgrade fails, fault F1005 is output with the corresponding fault value in
p0949.