EasyManua.ls Logo

Siemens SINUMERIK 840D sl - X1 Line Connection

Siemens SINUMERIK 840D sl
265 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Connection of the Components
5.3 Line Modules Interfaces Description
Guide for the SINUMERIK 840D sl machine configuring
5-18 Manual, 07/2006 Edition, 6FC5397-6CP10-0BA0
5.3.2.3 X1 line connection
Table 5-1 Terminal block X1 Active Line Module 16 kW
Terminal Technical specifications
U1
V1
W1
Max. connectable cross-section: 10 mm
2
Type: Screw terminal 6 (see Connection Methods)
Tightening torque: 1.5 - 1.8 Nm
PE connection Threaded hole M5/3 Nm
1
1
for ring cable lugs to DIN 46234
Table 5-2 Terminal block for the Active Line Module (36 kW to 120 kW)
Terminals Technical specifications
U1
V1
W1
Max. connection voltage:
3-ph. 480 V AC +10 % at 47 Hz to 63 Hz
36 kW:
Threaded bolt M6/6 Nm
1)
55 kW:
Threaded bolt M8/13 Nm
1)
80 kW to 120 kW:
Threaded bolt M8/13 Nm
1)
36 kW:
Threaded hole M6/6 Nm
1)
PE connection
55 kW:
Threaded hole M6/6 Nm
1)
80 kW to 120 kW:
Threaded hole M8/13 Nm
1
1
for ring cable lugs to DIN 46234

Table of Contents