Additional Information
8.2 Cooling Systems
Guide for the SINUMERIK 840D sl machine configuring
Manual, 07/2006 Edition, 6FC5397-6CP10-0BA0
8-3
8.2 8.2 Cooling Systems
8.2.1 Introduction
For the SINAMICS System S120, three cooling systems are differentiated:
Internal air cooling
External air cooling
Cold plate cooling
8.2.2 Internal Air Cooling
All SINAMICS S120 booksize components are installed within a control cabinet. The total
heat loss of all components is dissipated in the control cabinet. There are three ways to
remove the heat from the control cabinet:
Filter fan
Heat exchanger
Cooling unit
The device to be used depends on the associated environmental conditions and the required
cooling capacity. The configuring must also maintain the specified clearances for the
ventilation. No other components may be placed in these areas.
8.2.3 External Air Cooling
The external air cooling is a cooling system for SINAMICS booksize power units. The
through-hole technology is used for this construction form. The booksize power unit with its
heat sink can be placed in the rectangular cutout of the control cabinet rear wall and installed
with a seal. The heat sink with its cooling fins and fan (contained in scope of delivery)
extends at the back out of the control cabinet and the heat dissipation is made externally
from the control cabinet or in a separate air duct.

Table of Contents

Other manuals for Siemens SINUMERIK 840D sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840D sl and is the answer not in the manual?

Siemens SINUMERIK 840D sl Specifications

General IconGeneral
Control TypeCNC
Number of AxesUp to 31
Max Number of Channels10
InterfacesEthernet, PROFIBUS, PROFINET, USB
Interpolation5-axis interpolation
Operating Temperature0°C to 45°C
Relative HumidityUp to 95% (non-condensing)
DisplayTFT color display, various sizes
Programming LanguagesDIN/ISO
Safety FeaturesSafety Integrated
PLCIntegrated PLC S7-300
Drive InterfaceSINAMICS S120
Data StorageCF card, USB
Operating SystemWindows-based

Related product manuals