Connection of the Components
5.4 Motor Modules Interface Description
Guide for the SINUMERIK 840D sl machine configuring
5-34 Manual, 07/2006 Edition, 6FC5397-6CP10-0BA0
5.4.4 X21/X22 EP Terminals / Motor Module Temperature Sensor Connection
Note
The Motor Module is controlled using the -X21, -X22 terminal block and using DRIVE-CLiQ
at the -X200/201/202/203 terminal block. The detailed function description for the individual
signals and control/status words is contained in the SINAMICS S Parameter Manual.
To enable the Motor Module, the "infeed ready" signal must be connected from the Line
Module.
Table 5-14 Terminal block X21/X22
Terminal Function Technical data
1 +Temp
2 -Temp
Temperature sensor connection KTY84–1C130/PTC
3 EP +24 V (Enable Pulses)
4 EP M1 (Enable Pulses)
Supply voltage: 24 V DC (20.4 V - 28.8 V)
Current consumption: 10 mA
Optically isolated input
Signal propagation times:
L → H: 100 μs
H → L: 1000 μs
Max. connectable cross-section 1.5 mm
2
Type: Screw terminal 1 (see Connection Engineering section)
Notice
The KTY temperature sensor/the PTC must be connected with the correct polarity.
Note
The temperature sensor connection is required for motors for which the temperature value is
not transferred using DRIVE-CLiQ.
If the "Safe standstill" function is selected, for operation, ground must be placed at the -
X21:3 24 VDC and the -X21:4 terminal. For cancelation, a pulse suppression will be
activated.

Table of Contents

Other manuals for Siemens SINUMERIK 840D sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840D sl and is the answer not in the manual?

Siemens SINUMERIK 840D sl Specifications

General IconGeneral
Control TypeCNC
Number of AxesUp to 31
Max Number of Channels10
InterfacesEthernet, PROFIBUS, PROFINET, USB
Interpolation5-axis interpolation
Operating Temperature0°C to 45°C
Relative HumidityUp to 95% (non-condensing)
DisplayTFT color display, various sizes
Programming LanguagesDIN/ISO
Safety FeaturesSafety Integrated
PLCIntegrated PLC S7-300
Drive InterfaceSINAMICS S120
Data StorageCF card, USB
Operating SystemWindows-based