EasyManuals Logo

Siemens SINUMERIK 840D sl Manual

Siemens SINUMERIK 840D sl
265 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #122 background imageLoading...
Page #122 background image
Connection of the Components
5.5 DRIVE-CLiQ Topologies
Guide for the SINUMERIK 840D sl machine configuring
5-38 Manual, 07/2006 Edition, 6FC5397-6CP10-0BA0
5.5 5.5 DRIVE-CLiQ Topologies
5.5.1 DRIVE-CLiQ wiring
Introduction
The components of the SINAMICS S120 drive family and the control unit are interconnected
using DRIVE-CLiQ. When connecting the components, please note the following rules.
Rules for wiring DRIVE-CLiQ
The following rules must be observed when wiring DRIVE-CLiQ:
Ring wiring is not permitted.
Components must not be double-wired.
A maximum of 8 nodes can be connected in one row. A row is always regarded as
starting at the control unit.
Up to one Line Module, 6 Motor Modules (a Double Motor Module counts as 2 nodes)
and 3 direct measuring systems may be connected to one control unit.

Table of Contents

Other manuals for Siemens SINUMERIK 840D sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840D sl and is the answer not in the manual?

Siemens SINUMERIK 840D sl Specifications

General IconGeneral
Control TypeCNC
Number of AxesUp to 31
Max Number of Channels10
InterfacesEthernet, PROFIBUS, PROFINET, USB
Interpolation5-axis interpolation
Operating Temperature0°C to 45°C
Relative HumidityUp to 95% (non-condensing)
DisplayTFT color display, various sizes
Programming LanguagesDIN/ISO
Safety FeaturesSafety Integrated
PLCIntegrated PLC S7-300
Drive InterfaceSINAMICS S120
Data StorageCF card, USB
Operating SystemWindows-based