NCU/NX Terminal Assignment
3.3 Macros for commissioning
Guide for the SINUMERIK 840D sl machine configuring
Manual, 07/2006 Edition, 6FC5397-6CP10-0BA0
3-3
Overview
The table below lists macros for commissioning. Using the macros "1" or "5" allows a
standard terminal circuit to be achieved. This terminal circuit can be modified according to
the terminal plan.
Table 3-1 Macros for commissioning
Number File name Description
1 pm000001.acx Line Module with DRIVE-CLiQ :
• Interconnection p0840 (infeed)
• Interconnection 2. OFF 3 (rapid stop)
• Reserving input and output terminals for two SH/SBC groups
• Bero 1 – zero mark substitute
• 1. Probe
• 4 x Digital NC – Input ($A_IN[1] …[4] )
• Feedback Line Module
• 2 x digital NC – output ($A_OUT[1] …[2] )
ALM:
• Shutdown of network identification (p3410=0)
SLM with DRIVE-CLiQ:
• Network identification of the SLM is performed automatically
on the next pulse enable (p3410=5).
5 pm000005.acx Line Module without DRIVE-CLiQ :
• Interconnection p0864 to all drives
• Interconnection 2. OFF 3 (rapid stop)
• Reserving input and output terminals for two SH/SBC groups
• Bero 1 – zero mark substitute
• 1. Probe
• 4 x Digital NCK – Input ($A_IN[1] …[4] )
• 4 x digital NCK – output ($A_OUT[1] …[4] )
100116 pm100116.acx The following parameters are set on all 6 drives:
• Set up two encoder data sets p140=2
• Eight drive data sets p180=8
• Profibus protocol p922 = 116
150399 pm150399.acx Update of all drive components