EasyManua.ls Logo

Siemens SINUMERIK 840Di sl - 5.3.2 Displaying;editing tool data

Siemens SINUMERIK 840Di sl
560 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Motion commands
4.21 Travel to fixed stop (FXS, FXST, FXSW)
Fundamentals
Programming Manual, 11/2006, 6FC5398-1BP10-2BA0
191
The "Travel to fixed stop" commands can be called from synchronized actions/technology
cycles. They can be activated without initiation of a motion, the torque is limited
instantaneously. As soon as the axis is moved via a setpoint, the limit stop monitor is
activated.
Rise ramp
A rise ramp for the new torque limit can be defined by machine data to prevent any abrupt
changes to the torque limit setting (e.g., insertion of a quill).
Link and container axes
Travel to fixed stop is also permitted for
Link axes
Container axes
The status of the assigned machine axis is unaffected by container switches.
References: /FB2/Function Manual Extended Functions; Multiple Operator Panels and
NCUs. (B3)
This also applies to modal torque limiting with FOCON (see "travel with limited
torque/force").
Activation from synchronized actions
Example:
If the anticipated event ($R1) occurs and travel to fixed stop is not already operative, then
FXS must be activated for axis Y. The torque must correspond to 10% of the rated torque
value. The width of the monitoring window is set to the default.
N10 IDS=1 WHENEVER (($R1=1) AND ($AA_FXS[Y]==0)) DO $R1=0 FXS[Y]=1
FXST[Y]=10
The normal parts program must ensure that $R1 is set at the desired point in time.
Deactivation from synchronized actions
Example:
If an anticipated event ($R3) has occurred and the status "Limit stop contacted" (system
variable $AA_FXS) is reached, then FXS must be deselected.
N13 IDS=4 WHENEVER (($R3==1) AND ($AA_FXS[Y]==1)) DO FXS[Y]=0 FA[Y]=1000
POS[Y]=0
Fixed stop reached
When the fixed stop has been reached:
The distance-to-go is deleted and the position setpoint is manipulated,
The drive torque increases to the programmed limit value FXSW and then remains
constant,
Fixed stop monitoring is activated within the specified window width.

Table of Contents

Other manuals for Siemens SINUMERIK 840Di sl

Related product manuals