Parameter = 1
Write to log immediately. A main-run block is generated, which affects the
response in continuous-path mode.
Note
The words with F... and S... are used for time specifications only in the block with G4.
Any previously programmed feed F and spindle speed S remain valid.
Example
N10 G1 F200 Z-5 S300 M3
;Feed F; spindle speed S
N20 G4 F3
;Dwell time 3 s
N30 X40 Y10
N40 G4 S30
;Dwelling 30 revolutions of the spindle, corresponds
;at S=300 rpm and 100% speed override to:
;t=0.1 min
N40 X...
;Feed and spindle speed remain effective
5.9 Internal preprocessing stop
Function
The control generates an internal preprocessing stop on access to machine status data
($A...). If a command, which implicitly causes a preprocessing stop, is read in a following
block, this block is not executed until all other blocks, which have already been preprocessed
and stored, have been executed. The preceding block is halted in exact stop (as with G9).
Programming
Machine status data ($A...) are generated internally by the control.
Parameters
Status data of the machine ($A...).