Tables
12.4 List of predefined subprograms
Fundamentals
500 Programming Manual, 11/2006, 6FC5398-1BP10-2BA0
CPROT
INT: Number of
protection zone
INT: Option
0: Protection
zone OFF
1: Preactivate
protection zone
2: Protection
zone ON
3: Preactivate
protection zone
with conditional
stop, only with
protection zones
active.
REAL: Offset of
protection zone
in 1st geometry
axis
REAL: Offset of
protection zone
in 2nd geometry
axis
REAL: Offset of
protection zone
in 3rd geometry
axis
Channel-
specific
protection
zone
ON/OFF
NPROT INT: Number of
protection zone
INT: Option
0: Protection
zone OFF
1: Preactivate
protection zone
2: Protection
zone ON
3: Preactivate
protection zone
with conditional
stop, only with
protection zones
active
REAL: Offset of
protection zone
in 1st geometry
axis
REAL: Offset of
protection zone
in 2nd geometry
axis
REAL: Offset of
protection zone
in 3rd geometry
axis
Machine-
specific
protection
zone
ON/OFF
EXECUTE VAR INT: Error
status
EXECUTE: Activate program execution. This switches back to normal program
execution from reference point editing mode or after setting up a protection zone.
13. Preprocessing/single block
STOPRE Stop processing: Preprocessing stop until all prepared blocks are executed in main
run