EasyManua.ls Logo

Siemens siprotec 7SA522 - Page 603

Siemens siprotec 7SA522
628 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix
B-31
7SA522 Manual
C53000-G1176-C119-2
2906 >Start synchro-check (>Sync. Start) Synchronism
and Voltage
Check
SP on
off
* LED BI BO
2907 >Sync-Prog. Live bus / live line /
Sync (>Sync. synch)
Synchronism
and Voltage
Check
SP * * LED BI BO
2908 >Sync-Prog. Dead bus / live line (>
Usyn< U-line>)
Synchronism
and Voltage
Check
SP * * LED BI BO
2909 >Sync-Prog. Live bus / dead line (>
Usyn> U-line<)
Synchronism
and Voltage
Check
SP * * LED BI BO
2910 >Sync-Prog. Dead bus / dead line (>
Usyn< U-line<)
Synchronism
and Voltage
Check
SP * * LED BI BO
2911 >Sync-Prog. Override ( bypass )
(>Sync. o/ride)
Synchronism
and Voltage
Check
SP * * LED BI BO
2930 Synchro-check ON/OFF via BI
(Sync. on/off BI)
Synchronism
and Voltage
Check
IntSP ON
OFF
* LED BO
2931 Synchro-check is switched OFF
(Sync. OFF)
Synchronism
and Voltage
Check
OUT ON
OFF
* LED BO 41 31 1 GI
2932 Synchro-check is BLOCKED (Sync.
BLOCK)
Synchronism
and Voltage
Check
OUT ON
OFF
ON
OFF
LED BO 41 32 1 GI
2934 Synchro-check function faulty (Sync.
faulty)
Synchronism
and Voltage
Check
OUT ON
OFF
* LED BO 41 34 1 GI
2935 Synchro-check supervision time
expired (Sync.Tsup.Exp)
Synchronism
and Voltage
Check
OUT ON ON LED BO 41 35 1
2941 Synchronization is running (Sync.
running)
Synchronism
and Voltage
Check
OUT ON
OFF
ON LED BO 41 41 1 GI
2942 Synchro-check override/bypass
(Sync.Override)
Synchronism
and Voltage
Check
OUT ON
OFF
ON LED BO 41 42 1 GI
2943 Synchronism detected (Synchro-
nism)
Synchronism
and Voltage
Check
OUT ON
OFF
* LED BO 41 43 1 GI
2944 Sync. dead bus / live line detected
(Usyn< U-line>)
Synchronism
and Voltage
Check
OUT ON
OFF
* LED BO 41 44 1 GI
2945 Sync. live bus / dead line detected
(Usyn> U-line<)
Synchronism
and Voltage
Check
OUT ON
OFF
* LED BO 41 45 1 GI
2946 Sync. dead bus / dead line detected
(Usyn< U-line<)
Synchronism
and Voltage
Check
OUT ON
OFF
* LED BO 41 46 1 GI
F.No. Description Function Type of Infor-
mation
Log-Buffers Configurable in Matrix IEC 60870-5-103
Event Log On/Off
Trip (Fault) Log On/Off
Ground Fault Log On/Off
Marked in Oscill. Record
LED
Binary Input
Function Key
Binary Output
Event Log
Type
Information-No
Data Unit (ASDU)
General Interrogation

Table of Contents

Other manuals for Siemens siprotec 7SA522

Related product manuals