Appendix
B-33
7SA522 Manual
C53000-G1176-C119-2
3618 >BLOCK Z5-Trip (>BLOCK Z5-Trip) Distance pro-
tection, gen-
eral settings
SP ON
OFF
* LED BI BO 28 18 1 GI
3651 Distance is switched off (Dist. OFF) Distance pro-
tection, gen-
eral settings
OUT ON
OFF
* LED BO 28 51 1 GI
3652 Distance is BLOCKED (Dist.
BLOCK)
Distance pro-
tection, gen-
eral settings
OUT ON
OFF
ON
OFF
LED BO 28 52 1 GI
3653 Distance is ACTIVE (Dist. ACTIVE) Distance pro-
tection, gen-
eral settings
OUT * * LED BO 28 53 1 GI
3654 Setting error K0(Z1) or Angle K0(Z1)
(Dis.ErrorK0(Z1))
Distance pro-
tection, gen-
eral settings
OUT ON
OFF
* LED BO
3655 Setting error K0(>Z1) or Angle
K0(>Z1) (DisErrorK0(>Z1))
Distance pro-
tection, gen-
eral settings
OUT ON
OFF
* LED BO
3671 Distance PICKED UP (Dis. PICKUP) Distance pro-
tection, gen-
eral settings
OUT *
OFF
LED BO 28 71 2 GI
3672 Distance PICKUP L1 (Dis.Pickup L1) Distance pro-
tection, gen-
eral settings
OUT * * M LED BO 28 72 2 GI
3673 Distance PICKUP L2 (Dis.Pickup L2) Distance pro-
tection, gen-
eral settings
OUT * * M LED BO 28 73 2 GI
3674 Distance PICKUP L3 (Dis.Pickup L3) Distance pro-
tection, gen-
eral settings
OUT * * M LED BO 28 74 2 GI
3675 Distance PICKUP Earth (Dis.Pickup
E)
Distance pro-
tection, gen-
eral settings
OUT * * M LED BO 28 75 2 GI
3681 Distance Pickup Phase L1 (only)
(Dis.Pickup 1pL1)
Distance pro-
tection, gen-
eral settings
OUT * ON LED BO 28 81 2
3682 Distance Pickup L1E (Dis.Pickup
L1E)
Distance pro-
tection, gen-
eral settings
OUT * ON LED BO 28 82 2
3683 Distance Pickup Phase L2 (only)
(Dis.Pickup 1pL2)
Distance pro-
tection, gen-
eral settings
OUT * ON LED BO 28 83 2
3684 Distance Pickup L2E (Dis.Pickup
L2E)
Distance pro-
tection, gen-
eral settings
OUT * ON LED BO 28 84 2
3685 Distance Pickup L12 (Dis.Pickup
L12)
Distance pro-
tection, gen-
eral settings
OUT * ON LED BO 28 85 2
3686 Distance Pickup L12E (Dis.Pickup
L12E)
Distance pro-
tection, gen-
eral settings
OUT * ON LED BO 28 86 2
F.No. Description Function Type of Infor-
mation
Log-Buffers Configurable in Matrix IEC 60870-5-103
Event Log On/Off
Trip (Fault) Log On/Off
Ground Fault Log On/Off
Marked in Oscill. Record
LED
Binary Input
Function Key
Binary Output
Event Log
Type
Information-No
Data Unit (ASDU)
General Interrogation

Table of Contents