Appendix
B-37
7SA522 Manual
C53000-G1176-C119-2
3802 Distance TRIP command - Only
Phase L1 (Dis.Trip 1pL1)
Distance pro-
tection, gen-
eral settings
OUT * ON LED BO 28 202 2
3803 Distance TRIP command - Only
Phase L2 (Dis.Trip 1pL2)
Distance pro-
tection, gen-
eral settings
OUT * ON LED BO 28 203 2
3804 Distance TRIP command - Only
Phase L3 (Dis.Trip 1pL3)
Distance pro-
tection, gen-
eral settings
OUT * ON LED BO 28 204 2
3805 Distance TRIP command Phases
L123 (Dis.Trip 3p)
Distance pro-
tection, gen-
eral settings
OUT * ON LED BO 28 205 2
3811 Distance TRIP single-phase Z1
(Dis.TripZ1/1p)
Distance pro-
tection, gen-
eral settings
OUT * * LED BO 28 211 2
3813 Distance TRIP single-phase Z1B
(Dis.TripZ1B1p)
Distance pro-
tection, gen-
eral settings
OUT * * LED BO 28 213 2
3816 Distance TRIP single-phase Z2
(Dis.TripZ2/1p)
Distance pro-
tection, gen-
eral settings
OUT * * LED BO 28 216 2
3817 Distance TRIP 3phase in Z2
(Dis.TripZ2/3p)
Distance pro-
tection, gen-
eral settings
OUT * * LED BO 28 217 2
3818 Distance TRIP 3phase in Z3
(Dis.TripZ3/T3)
Distance pro-
tection, gen-
eral settings
OUT * * LED BO 28 218 2
3821 Distance TRIP 3phase in Z4
(Dis.TRIP 3p. Z4)
Distance pro-
tection, gen-
eral settings
OUT * * LED BO 28 209 2
3822 Distance TRIP 3phase in Z5
(Dis.TRIP 3p. Z5)
Distance pro-
tection, gen-
eral settings
OUT * * LED BO 28 210 2
3823 DisTRIP 3phase in Z1 with single-ph
Flt. (DisTRIP3p. Z1sf)
Distance pro-
tection, gen-
eral settings
OUT * * LED BO 28 224 2
3824 DisTRIP 3phase in Z1 with multi-ph
Flt. (DisTRIP3p. Z1mf)
Distance pro-
tection, gen-
eral settings
OUT * * LED BO 28 225 2
3825 DisTRIP 3phase in Z1B with single-
ph Flt (DisTRIP3p.Z1Bsf)
Distance pro-
tection, gen-
eral settings
OUT * * LED BO 28 244 2
3826 DisTRIP 3phase in Z1B with multi-ph
Flt. (DisTRIP3p Z1Bmf)
Distance pro-
tection, gen-
eral settings
OUT * * LED BO 28 245 2
3850 DisTRIP Z1B with Teleprotection
scheme (DisTRIP Z1B Tel)
Distance pro-
tection, gen-
eral settings
OUT * * LED BO 28 251 2
4001 >Distance Teleprotection ON
(>Dis.Telep. ON)
Teleprotec-
tion for Dis-
tance prot.
SP * * LED BI BO
F.No. Description Function Type of Infor-
mation
Log-Buffers Configurable in Matrix IEC 60870-5-103
Event Log On/Off
Trip (Fault) Log On/Off
Ground Fault Log On/Off
Marked in Oscill. Record
LED
Binary Input
Function Key
Binary Output
Event Log
Type
Information-No
Data Unit (ASDU)
General Interrogation

Table of Contents