1496 BF Pole discrepancy pickup (BF CBdis-
crSTART)
Breaker Failure OUT * ON
OFF
LED BO
1497 BF Pole discrepancy pickup L1 (BF
CBdiscr L1)
Breaker Failure OUT * ON
OFF
LED BO
1498 BF Pole discrepancy pickup L2 (BF
CBdiscr L2)
Breaker Failure OUT * ON
OFF
LED BO
1499 BF Pole discrepancy pickup L3 (BF
CBdiscr L3)
Breaker Failure OUT * ON
OFF
LED BO
1500 BF Pole discrepancy Trip (BF CBdiscr
TRIP)
Breaker Failure OUT * ON LED BO
1503 >BLOCK Thermal Overload Protection
(>BLK ThOverload)
Thermal Overload SP ON
OFF
* LED BI BO 167 3 1 GI
1511 Thermal Overload Protection OFF
(Th.Overload OFF)
Thermal Overload OUT ON
OFF
* LED BO 167 11 1 GI
1512 Thermal Overload Protection BLOKKED
(Th.Overload BLK)
Thermal Overload OUT ON
OFF
ON
OFF
LED BO 167 12 1 GI
1513 Thermal Overload Protection ACTIVE
(Th.O/L ACTIVE)
Thermal Overload OUT ON
OFF
* LED BO 167 13 1 GI
1515 Th. Overload: Current Alarm (I alarm)
(Th.O/L I Alarm)
Thermal Overload OUT ON
OFF
* LED BO 167 15 1 GI
1516 Th. Overload Alarm: Near Thermal Trip
(Th.O/L Θ Alarm)
Thermal Overload OUT ON
OFF
* LED BO 167 16 1 GI
1517 Th. Overload Pickup before trip (Th.O/L
Pickup)
Thermal Overload OUT ON
OFF
* LED BO 167 17 1 GI
1521 Th. Overload TRIP command (Th.O/L
TRIP)
Thermal Overload OUT * ON M LED BO 167 21 1
2054 Emergency mode (Emer. mode) Backup overcur-
rent
OUT ON
OFF
ON
OFF
LED BO 128 37 1 GI
2701 >AR: Switch on auto-reclose function
(>AR on)
Automatic Reclo-
sure
SP * * LED BI BO 40 1 1
2702 >AR: Switch off auto-reclose function
(>AR off)
Automatic Reclo-
sure
SP * * LED BI BO 40 2 1
2703 >AR: Block auto-reclose function (>AR
block)
Automatic Reclo-
sure
SP ON
OFF
* LED BI BO 40 3 1 GI
2711 >External start of internal Auto reclose
(>AR Start)
Automatic Reclo-
sure
SP * ON LED BI BO 40 11 2 GI
2712 >AR: External trip L1 for AR start (>Trip L1
AR)
Automatic Reclo-
sure
SP * ON LED BI BO 40 12 2 GI
2713 >AR: External trip L2 for AR start (>Trip L2
AR)
Automatic Reclo-
sure
SP * ON LED BI BO 40 13 2 GI
2714 >AR: External trip L3 for AR start (>Trip L3
AR)
Automatic Reclo-
sure
SP * ON LED BI BO 40 14 2 GI
2715 >AR: External 1pole trip for AR start (>Trip
1pole AR)
Automatic Reclo-
sure
SP * ON LED BI BO 40 15 2 GI
2716 >AR: External 3pole trip for AR start (>Trip
3pole AR)
Automatic Reclo-
sure
SP * ON LED BI BO 40 16 2 GI
2727 >AR: Remote Close signal (>AR Remote-
Close)
Automatic Reclo-
sure
SP * ON LED BI BO 40 22 2 GI
F.No. Description Function Type of
Informa-
tion
Log-Buffers Configurable in Matrix IEC 60870-5-103
Event Log On/Off
Trip (Fault) Log On/Off
Ground Fault Log On/Off
Marked in Oscill. Record
LED
Binary Input
Function Key
Binary Output
Chatter Blocking
Type
Information-No
Data Unit (ASDU)
General Interrogation