Appendix
B-51
7SA6 Manual
C53000-G1176-C156-2
6856 >Trip circuit superv. 2: Trip Relay (>TripC2
TripRel)
Trip Circuit Super-
vision
SP ON
OFF
* LED BI BO
6857 >Trip circuit superv. 2: Breaker Relay
(>TripC2 Bkr.Rel)
Trip Circuit Super-
vision
SP ON
OFF
* LED BI BO
6858 >Trip circuit superv. 3: Trip Relay (>TripC3
TripRel)
Trip Circuit Super-
vision
SP ON
OFF
* LED BI BO
6859 >Trip circuit superv. 3: Breaker Relay
(>TripC3 Bkr.Rel)
Trip Circuit Super-
vision
SP ON
OFF
* LED BI BO
6861 Trip circuit supervision OFF (TripC OFF) Trip Circuit Super-
vision
OUT ON
OFF
* LED BO
6865 Failure Trip Circuit (FAIL: Trip cir.) Trip Circuit Super-
vision
OUT ON
OFF
* LED BO 128 36 1 GI
6866 TripC1 blocked: Binary input is not set
(TripC1 ProgFAIL)
Trip Circuit Super-
vision
OUT ON
OFF
* LED BO
6867 TripC2 blocked: Binary input is not set
(TripC2 ProgFAIL)
Trip Circuit Super-
vision
OUT ON
OFF
* LED BO
6868 TripC3 blocked: Binary input is not set
(TripC3 ProgFAIL)
Trip Circuit Super-
vision
OUT ON
OFF
* LED BO
7104 >BLOCK Backup OverCurrent I>>
(>BLOCK O/C I>>)
Backup overcur-
rent
SP ON
OFF
* LED BI BO 64 4 1 GI
7105 >BLOCK Backup OverCurrent I>
(>BLOCK O/C I>)
Backup overcur-
rent
SP ON
OFF
* LED BI BO 64 5 1 GI
7106 >BLOCK Backup OverCurrent Ip
(>BLOCK O/C Ip)
Backup overcur-
rent
SP ON
OFF
* LED BI BO 64 6 1 GI
7110 >Backup OverCurrent InstantaneousTrip
(>O/C InstTRIP)
Backup overcur-
rent
SP ON
OFF
ON
OFF
LED BI BO 64 10 1 GI
7130 >BLOCK I-STUB (>BLOCK I-STUB) Backup overcur-
rent
SP ON
OFF
* LED BI BO 64 30 1 GI
7131 >Enable I-STUB-Bus function (>I-STUB
ENABLE)
Backup overcur-
rent
SP ON
OFF
ON
OFF
LED BI BO 64 31 1 GI
7151 Backup O/C is switched OFF (O/C OFF) Backup overcur-
rent
OUT ON
OFF
* LED BO 64 51 1 GI
7152 Backup O/C is BLOCKED (O/C BLOCK) Backup overcur-
rent
OUT ON
OFF
ON
OFF
LED BO 64 52 1 GI
7153 Backup O/C is ACTIVE (O/C ACTIVE) Backup overcur-
rent
OUT * * LED BO 64 53 1 GI
7161 Backup O/C PICKED UP (O/C PIKKUP) Backup overcur-
rent
OUT *
OFF
M LED BO 64 61 2 GI
7162 Backup O/C PICKUP L1 (O/C Pickup L1) Backup overcur-
rent
OUT * ON LED BO 64 62 2 GI
7163 Backup O/C PICKUP L2 (O/C Pickup L2) Backup overcur-
rent
OUT * ON LED BO 64 63 2 GI
7164 Backup O/C PICKUP L3 (O/C Pickup L3) Backup overcur-
rent
OUT * ON LED BO 64 64 2 GI
7165 Backup O/C PICKUP EARTH (O/C Pickup
E)
Backup overcur-
rent
OUT * ON LED BO 64 65 2 GI
7171 Backup O/C Pickup - Only EARTH (O/C
PU only E)
Backup overcur-
rent
OUT * ON LED BO 64 71 2
F.No. Description Function Type of
Informa-
tion
Log-Buffers Configurable in Matrix IEC 60870-5-103
Event Log On/Off
Trip (Fault) Log On/Off
Ground Fault Log On/Off
Marked in Oscill. Record
LED
Binary Input
Function Key
Binary Output
Chatter Blocking
Type
Information-No
Data Unit (ASDU)
General Interrogation