Mounting and dismantling
4.4 Installing, mounting and removing the 3RW5 HMI
SIRIUS 3RW52 Soft Starter
Equipment Manual, 04/2020, A5E35630451002A/RS-AE/005
61
4.4.3 Installing the High Feature 3RW5 HMI in the 3RW52 soft starter
Requirements
3RW5 HMI High Feature (accessory)
HMI connecting cable, 0.1 m (accessory)
Hinged cover for 3RW52 with cutout for 3RW5 HMI High Feature (accessory) or
Cut out the hinged cover for 3RW5 HMI (Page 75)
Procedure
NOTICE
Material damage caused by electrostatic charge
Note the information in chapter ESD Guidelines (Page 15).
Illustration similar
Observe the coding of the plug and socket / .
Lock the connector in the socket
.
Observe the cable routing:
Cable routing to the right
Cable routing to the left
Replace the hinged cover of the 3RW52 soft starter as required. (Page 76)
Result
You have installed the 3RW5 HMI High Feature in the 3RW52 soft starter and can
commission it (Page 129).