Appendix A
A.1 Modbus, EIP, HART & N2 Profile Mappings
F US Clamp-on Communications Protocol Manual
140 Hardware Installation Manual, 11/2015, A5E34981613-AC
C1 Analog
Input 1
30277 4 Real Analog_In 15 Float n/a ADF(Float) 10 1
C1 AI1 Units
30797
8
String
String_In
32
UINT16
n/a
BD(Byte)
65
8
C1 Percent
Deviation
30189 4 Real Analog_In 16 Float n/a ADF(Float) 11 1
C1 Deviation
Units
30645 8 String String_In 36 UINT16 n/a BD(Byte) 73 8
C1 Chiller
Efficiency 1
30213 4 Real Analog_In 17 Float n/a ADF(Float) 12 1
C1 Chiller
Efficiency 2
30219 4 Real Analog_In 18 Float n/a ADF(Float) 13 1
C1 Chiller
Efficiency 3
30225 4 Real Analog_In 19 Float n/a ADF(Float) 14 1
C1 CE Units
30669
8
String
String_In
40
UINT16
n/a
BD(Byte)
81
8
C2 Site ID
30505
8
String
String_In
44
UINT16
n/a
BD(Byte)
89
8
C2 Avg Energy
Rate
30203 4 Real Analog_In 20 Float 129 41-29h Q ADF(Float) 15 1
C2 Inst.Energy
Rate
30197 4 Real Analog_In 21 Float n/a ADF(Float) 16 1
C2 Energy Rate
Units
30657 8 String String_In 48 UINT16 131 41-29h BD(Byte) 97 8
C2 Energy Total
30209
4
Real
Analog_In
22
Float
129
44-2Ch
ADF(Float)
17
1
C2 EnergyTotal
Units
30665 8 String String_In 52 UINT16 131 44-2Ch BD(Byte) 105
8
C2 Inst.Flow
Rate
30111 4 Real Analog_In 23 Float 129 7-07h ADF(Float) 18 1
C2 Avg Flow
Rate
30123 4 Real Analog_In 24 Float 129 2-02h T ADF(Float) 19 1
C2 Flow Rate
Units
30521 8 String String_In 56 UINT16 131 2-02h BD(Byte) 113
8
C2 Total
30147
4
Real
Analog_In
25
Float
129
35-23h
ADF(Float)
20
1
C2 Total Units
30561
8
String
String_In
60
UINT16
131
35-23h
BD(Byte)
121
8
C2 Supply Temp
30305
4
Real
Analog_In
26
Float
n/a
ADF(Float)
21
1
C2 Supply Temp
Units
30777 8 String String_In 64 UINT16 n/a BD(Byte) 129
8
C2 Return Temp
30311
4
Real
Analog_In
27
Float
n/a
ADF(Float)
22
1
C2 Return Temp
Units
30785 8 String String_In 68 UINT16 n/a BD(Byte) 137
8
C2 Temp
Difference
30317 4 Real Analog_In 28 Float n/a ADF(Float) 23 1
C2 Temp Diff
Units
30793 8 String String_In 72 UINT16 n/a BD(Byte) 145
8
C2 Status
/Alarms: Spacing
10041 1 Bit Coil Binary_In 1 UINT16 n/a DI(Dig In) 10 1
C2 Status
/Alarms: Empty
10042 1 Bit Coil Binary_In 1 UINT16 n/a DI(Dig In) 12 1
C2 Status
/Alarms: Rate
10043 1 Bit Coil Binary_In 1 UINT16 n/a DI(Dig In) 13 1