EasyManua.ls Logo

Siemens SITRANS F US - Page 168

Siemens SITRANS F US
194 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix A
A.1 Modbus, EIP, HART & N2 Profile Mappings
F US Clamp-on Communications Protocol Manual
166 Hardware Installation Manual, 11/2015, A5E34981613-AC
Status: Pig
Path 1
10029 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 10 1
Status: Zeromatic
Path 1
10030 1 Bit Coil Binary_In 0 UINT16 n/a DI(Dig In) 2 1
Status: Spacing
Path 2
10041 1 Bit Coil Binary_In 1 UINT16 n/a DI(Dig In) 11 1
Status: Empty
Path 2
10042 1 Bit Coil Binary_In 1 UINT16 n/a DI(Dig In) 13 1
Status: Rate
Path 2
10043 1 Bit Coil Binary_In 1 UINT16 n/a DI(Dig In) 14 1
Status: Fault
Path 2
10044 1 Bit Coil Binary_In 1 UINT16 n/a DI(Dig In) 15 1
Status: Aeration
Path 2
10045 1 Bit Coil Binary_In 1 UINT16 n/a DI(Dig In) 16 1
Status: Memory
Path 2
10046 1 Bit Coil Binary_In 1 UINT16 n/a DI(Dig In) 17 1
Status: Makeup
Path 2
10047 1 Bit Coil Binary_In 1 UINT16 n/a DI(Dig In) 18 1
Status: Interface
Path 2
10048 1 Bit Coil Binary_In 1 UINT16 n/a DI(Dig In) 19 1
Status: Pig
Path 2
10049 1 Bit Coil Binary_In 1 UINT16 n/a DI(Dig In) 20 1
Status: Zeromatic
Path 2
10050 1 Bit Coil Binary_In 1 UINT16 n/a DI(Dig In) 12 1
Status/Alarms:
Spacing
10001 1 Bit Coil Binary_In 2 UINT16 n/a DI(Dig In) 21 1
Status/Alarms:
Empty
10002 1 Bit Coil Binary_In 2 UINT16 n/a DI(Dig In) 23 1
Status/Alarms:
Rate
10003 1 Bit Coil Binary_In 2 UINT16 n/a DI(Dig In) 24 1
Status/Alarms:
Fault
10004 1 Bit Coil Binary_In 2 UINT16 n/a DI(Dig In) 25 1
Status/Alarms:
Aeration
10005 1 Bit Coil Binary_In 2 UINT16 n/a DI(Dig In) 26 1
Status/Alarms:
Memory
10006 1 Bit Coil Binary_In 2 UINT16 n/a DI(Dig In) 27 1
Status/Alarms:
Makeup
10007 1 Bit Coil Binary_In 2 UINT16 n/a DI(Dig In) 28 1
Status/Alarms:
Interface
10008 1 Bit Coil Binary_In 2 UINT16 n/a DI(Dig In) 29 1
Status/Alarms:
Pig
10009 1 Bit Coil Binary_In 2 UINT16 n/a DI(Dig In) 30 1
Status/Alarms:
Zeromatic
10010 1 Bit Coil Binary_In 2 UINT16 n/a DI(Dig In) 22 1
Temperature 1
30293
4
Real
Analog_In
27
Float
n/a
ADF(Float)
22
1
Temperature 2
30295
4
Real
Analog_In
28
Float
n/a
ADF(Float)
23
1
Temp Units
30753
8
String
String_In
60
UINT16
n/a
BD(Byte)
121
8
Delta Time
Path 1
30179 4 Real Analog_In 29 Float n/a ADF(Float) 24 1
Delta Time
Path 2
30181 4 Real Analog_In 30 Float n/a ADF(Float) 25 1

Table of Contents

Other manuals for Siemens SITRANS F US

Related product manuals