Weighing Functions
SIWAREX FTA
Range of Values / Explanation
controller
0: No control for switching off the rough-/fine-signal
1: Proportional controller without fine signal time
controller
2: Proportional controller with fine-signal time
controller
3: Fine signal time controller without proportional
controller
Other definitions not permitted.
Proportional controller
Other definitions not permitted.
Maximum one-time
control access
Limitation for maximum one-time control access
of proportional controller
max
max
Definition of set time for the fine signal-time controller
controller
Other definitions not permitted.
The overlapping time must be less than the
emptying time The next scale start can be
performed early by the amount of overlapping
0: Emptying depending on empty range
>0: Empty after defined time
0: Monitoring switched off
>0: After the emptying time has elapsed and the
empty range has not been achieved, a technology
0: All weighing procedures in the loading
operation are controlled with coarse and fine
signal
1: The last 5 weighing procedures are run with
coarse and fine signals
2: The last 4 weighing procedures are run with
coarse and fine signals
4: The last 3 weighing procedures are run with
coarse and fine signals
8: The last 2 weighing procedures are run with
coarse and fine signals
16: The last 1 weighing procedure is run with
coarse and fine signals
Other values are not used