Commands
SIWAREX FTA
in following
operating
All parameters are set to the status that was
assigned originally by the manufacturer.
operation
Operating errors and fatal system errors that have
led to a reboot are acknowledged. The error status
is abandoned if no other operating errors exist.
The resistance of the load cells is measured and
compared with the stored impedance reference
value.
cycle, Service
The resistance of the load cells is determined and
stored as a reference value for future impedance
checks.
cycle, Service
Switch on stand-alone operation
The instruction switches stand-alone operation on.
The instruction is saved i.e.after switching the
power supply off and switching it on again, the
module remains in stand-alone operation.
Special features:
Stand-alone operation is deactivated automatically
as soon as the module is operated in SIMATIC
(see also 4.2).
not on SIMATIC
bus
Switch off stand-alone operation
The instruction switches stand-alone operation off.
Special features:
Stand-alone operation is deactivated automatically
as soon as the module is operated in SIMATIC
(see also 4.2).
The instruction sets the slave pointer (see 5.17)
back to 0.