Commands
SIWAREX FTA
6-133
Code
Command explanation
Executable
in following
operating
states
110
Residual weighing
If required, a running weighing procedure is
stopped and the emptying process is started
immediately. The current weight is balanced before
emptying. In certain cases, continuous operation is
ended.
Stopped, Dosing
cycle
111
Activate inhibition time
The weight value is not determined for a configured
time period. Furthermore, the measurement value
error (operating error 17) is suppressed during this
period. The defined time can be shortened and
thus the inhibition time ended immediately using
command 112.
All
112
Deactivate inhibition time
The activated inhibition time is stopped
prematurely.
All
113
Logging and deleting calibratable totalizing
memory 1
This command is only executed if total 1 is
contained in log text 1.
No weighing
cycle
114
Deletes totalizing memory 1
Permitted only if country code is not “OIML
No weighing
cycle
115
Deletes totalizing memory 2
Totalising memory 2 can be deleted at any time.
No weighing
cycle