Commands
SIWAREX FTA
in following
operating
Continue the weighing cycle. Weighing and
emptying are continued with this command.
Continue weighing with pulse dosing
Weighing is continued in pulse dosing operation
only (Pulse / Pause).
Stop (halt immediately) in weighing cycle
Stops immediately for weighing or emptying, the
scale stops and remains in “stopped” status.
Possible commands to follow:
103 – Continue
104 – Continue weighing with pulse dosing
108 – Abort
110 – Residual weighing
The current weighing is completed and then the
continuous operation is ended.
weighing cycle
The scale is stopped at the next defined step for
the check stop. Continued with:
103 – Continue
104 – Continue weighing with pulse dosing
108 – Abort
110 – Residual weighing
The stopped weighing cycle is ended with no
further activity. No automatic emptying is
performed. The previous weight is not taken into
account in the totalising calculation.
This command activates the emptying signal in
halted-state (no weighing cycle active) If the
emptying time is 0 then the emptying signal is
activated until the weight is in the empty range.
Independent from this, the emptying can be ended
with command 118.
cycle