Commands
SIWAREX FTA
in following
operating
The recorded data (trace function) stored in the
Micro Memory Card are deleted.
The stored data (trace function) in the RAM
memory are deleted.
The Micro Memory Card parameters are defined
corresponding with the definitions in the module data.
All of the stored content in the MMC is deleted.
operation
Delete all MMC data (log data, measurement
data, …)
The data stored in the Micro Memory Card are
deleted.
operation
The instruction causes a single recording of a trace
element. The time intervals between two trace
recordings do not require a fixed definition. With a
trace to MMC, renewed trace instructions will only
lead to a new trace recording after 50 ms. With
tracing to RAM, the recording is executed within
max. 10 ms.
Start weighing with tare zero setting mode
Start weighing with previous zero setting or taring
corresponding with the setting for tare / zero setting
mode.
cycle, No
service
Start weighing without tare zero setting mode
Start weighing without zero setting or taring. This is
only permitted in non-calibratable operation
(country code not “OIML”).
cycle, No
service
Start continuous weighing
Continuous start of sequential weighing cycles.
(Only possible in operating AWI mode)
cycle, No
service