Messages and Diagnostics
SIWAREX FTA
No.
command errors -
Max. Single controller access
Controller Optimum Plus/Minus
Checksum error in data record 26 or 27.
The data was falsified or the DR versions do not match.
unknown
In the parameters, there is a number for selecting a characteristic
which has no meaning. The following values must be retained:
DR3:
Source for weight simulation 0..2
Decade for the curve 0..6
Source for the analog output 0..4
DR23:
Filter type 0..2
Limit frequency Filter 0..9
Tare-/Zero setting mode 0..4
Controller type selection 0..3
Impedance error is generated if the deviation in impedance is
greater than 10 % of the reference value or if an error has
occurred in the measurement
General data and
command errors
You cannot write to the selected data record if write protection is
set.
Table 7-1 List of Data and Operating Errors