Messages and Diagnostics
SIWAREX FTA
7-152
Error
No.
Technology message - description
Solution
12
Timeout print-out
A print job was not complete within the
predefined monitor time for logging in DR4.
Check the output device or increase the
monitoring time.
13
Error Output device not ready
Logging not possible because the defined
output device is not ready.
If the printer is defined as the output device,
check whether the printer is connected
properly and that it is installed and ready for
operation.
If the output device is selected as the MMC,
check for whether a formatted MMC is
inserted.
14
Logging not possible since the weight
lies outside of the weighing range
Logging is not possible because the weight lie
outside of the weighing range for a
calibratable application (Code in DR3 OIML).
15
Reserved
16
Logging not possible, Protokoll-ID error
Logging is not possible because no protocol
ID was defined in the protocol string
(calibratable application, Code in DR3 -
OIML).
17
Logging is not possible, printer not ready
Logging is not possible because the printer
has not indicated that it is ready. Check the
printer.
18
Logging is not possible, MMC is
defective
Logging is not possible because the MMC is
defective or has been removed. Change the
MMC or insert a formatted MMC.
19
Logging is not possible, SIWATOOL
program is active
Logging is not possible because the
SIWATOOL program is active on the
interface. Disconnect the connection to the
PC and connect a printer.
20
Reserved
21-40
Weighing function error
21
Weighing command thrown out for lack
of a standstill
Taring/zero setting or logging is not possible
because no standstill was achieved within
standstill time 1 in DR 3.
22
Zero setting is not possible
The start-up weight lies outside of the defined
value range defined in DR 3 for the maximum
positive and negative weight for zero setting.
23
Zero setting / taring not possible
Zero positions or zero setting not possible
because the gross lies outside the zero
setting range or taring not possible because
the tare maximum load has been exceeded.
24
Reserved
25
Reserved
26
Reserved
27
Reserved

Table of Contents