Technical Data
SIWAREX FTA
14-187
14.11 Electrical, EMC and climatic requirements
14.11.1 Electrical protection and safety requirements
Met requirements
Standards
Remarks
Safety guidelines IEC 61010-1;
IEC 61131; UL 508;
CSA C22.2 No.142;
FM 3611 class I, Div.2;
UL-/CSA-/FM Zone 2
certification upon request
Protection class
IEC 61140
Protection class I, with
protective conductor
IP protection
IP 20 nach IEC 60529
Protection against
contact with standard
test fingers
Protection against
foreign bodies with
diameters above
12.5 mm
No special protection against
Air and creepage distances IEC 61131
UL508
CSA C22.2 No.142
Surge category II
Pollution degree 2
Circuit board material IIIa
Circuit track spacing 0.5 mm
Isolation test IEC 61131-2:
CSA C22.2 No.142
Test voltage 500 V DC
Fire and burn protection for Open Type Controller”:
IEC 61131-2:; UL 508
Material
SN 36350 (3.93)
Table 14-11 Data: Electrical protection and safety requirements
14.11.2 Electromagnetic Compatibility
interference emission (industrial use): EN 61000-6-4
Comments
Standard
Limit values
Emission of radio interference
(electromagnetic fields)
IEC 61131-2
EN 55011 Class A, Group 1
30 230 MHz: < 40dB(µV/m) Q
230-1000MHz: < 47dB(µV/m) Q
Emission on power supply
lines
IEC 61131-2
EN 55011 Class A, Group 1
EN 55014