401925/C
63
Specifyanangle(indegrees)tocompensateforanydeviationfromthe
Zaxis(verticaldirection)inthecoordinatesystem.
Keepinmindthatinitsdefaultposition(allaxissetto0(zero))thetransducer
pointsstraightdownwiththeorientationmark(arrow)pointingforward.This
defaultpositionmustalwaysbeusedasreferenceforrotationadjustments.To
settheanglescorrectly,observethisexercise.
1Startwiththetransducerinitsdefaultposition:Thetransducerface
ishorizontalfacingdown,andtheindicatorarrowispointingstraight
forward.
2Ifthetransducerisproperlyinstalledwithoutunintentionalskew,the
RotationaroundXcanalsobesetto0(zero).
3Liftthefrontendofthetransducerup,sothattheindicatorarrowmoves
up.ThisisaRotationaroundY.
4Proceeduntiltherequestedanglehasbeenreached.
Example:Ifa30-degreeYangleisrequested,theRotationaroundYmust
besetto60degrees(thatistheanglefromthedefaultposition).Since
thetransducerispointingstraightforward,theRotationaroundZvalue
is0(zero).
5Fromthisraisedposition,turnthetransducertowardsstarboard.The
indicatorarrowisstillpointingup.ThisisaRotationaroundZ.
6Proceeduntiltherequestedanglehasbeenreached.
Example:Ifa90-degreeZangleisrequested,theRotationaroundZmust
besetto90degrees(thatistheanglefromtheforwardposition).
11SelectAddtosavetheinformationyouhaveprovided.
ThetransducerisaddedtothelistintheInstalledTransducersbox.
12Repeatforeachtransducerthatyouwishtoinstall.
13ContinueyourworkintheInstallationdialogbox,orselectOKtocloseit.
Result
Onceatransducerhasbeeninstalled,itislistedintheInstalledTransducersbox.Tosee
theinformationyouhavecollectedaboutthetransducer,selecttherelevanttransducer
inthelist.
TheEditfunctionalityontheTransducerInstallationpagemakesitpossibletochange
theinformationyouhaveprovidedforthetransducer.Youcannotchangethemodel
identicationandtheserialnumber.Thecustomnameisusedseveralplacesintheuser
interface,anditcanbechanged.
TheRemovefunctionalityontheTransducerInstallationpagemakesitpossibletodelete
theinformationyouhaveprovidedforthetransducer.Thereisno"undo"functionality.