EasyManua.ls Logo

Simrad GC80 Compact MK2 - 8 Technical Specifications; Accuracy; General Specifications

Simrad GC80 Compact MK2
121 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Simrad GC80/85 Compact MK2 Gyro Compass
988-12718-003 76
8 TECHNICAL SPECIFICATIONS
This section lists all specifications for the GC80/85 Gyro compasses.
8.1 Accuracy
Settling time: .......................................................................................... within 3 hours
(If startup heading is within +/-5° of actual heading)
Settle point error: .................................................................................. less than ±0.
RMS value of the difference: ................................................................ less than 0.1º
Repeatability of settle point error: ................................................... less than ±0.
Roll and pitch error: .............................................................................. less than ±0.
Static error:.............................................................................................. less than ±0.1°
Settle point error under general conditions: ................................less than ±0.5°
GC85
Speed and acceleration error ............................................................less than ±2.0°
Maximum acceleration must not exceed 2m
2
.
Note!
Accuracy at equator. For other latitudes, accuracy to be multiplied by
*(1/COS f), where f = Latitude.
8.2 General specifications
Follow-up speed (follow-up system) ......................................................... > 75°/sec
Gimbal freedom ........................................................... for both roll and pitch: ±4
Range of speed correction:
...................................... 0-50 knots (GC80) / latitude (0° - +70°)
...................................... 0-70 knots (GC85) / latitude (0° - +70°)
Main power supply: ....................................................................................... 24V DC or
Option: ................................. 100/110/115/200 V AC, 50/60 Hz
Power supply for alarm and backup:................................................ 24 V DC, 70 W
Voltage fluctuation: ........................................................................................ AC ±10%
DC -20% - +30%
Power consumption:
Start (Master): ................................................................ within 140 VA
Ordinary (Master): .......................................................... within 70 VA
Repeater: ........................................................................ within 150 VA
Repeater type: .................................................................................. 24 V DC 6 step/°
Number of step repeater connections:.................................................................... 1
Number of NMEA connections: ................................................................................. 4
Repeater backup circuits: ....................................................................................... 1+4