Please turn the main power switch off before performing procedures in laser unit. Laser can cause
severe eye damages.
Performing controls, adjustments or procedures other than said from this manual can cause
severe radiation exposures.
LSU Replacement
Please check if main power switch has turned off and power cable is pulled from outlet before
disassembling or adjusting the laser unit.
<L/LF MODEL>
5. Open the front door
6. Remove the rear cover
7. Remove left and right covers
8. Remove the upper cover.
9. Remove 3 screws [A] on the laser unit.
10. Remove the laser unit from the frame.
11. Remove the laser unit cables [B].
<MF/HF MODEL>
12. Open the front door
13. Remove the rear cover
14. Remove left and right covers
15. Remove the upper cover.
16. Remove laser unit’s FLAT CABLE and motor harness connector