2Safety instructions Sirona Dental Systems GmbH
2.3On-site installation Operating Instructions INTEGO
2.3
On-site installation
The on-site installation must have been performed according to our
requirements. The details are described in the document "Installation
Requirements".
2.4
Installation of the treatment center
Installation must be carried out by authorized personnel according to the
installation instructions.
2.5
Media quality
The air and water supplies must meet the requirements specified in the
installation requirements.
Disinfection system, optional or with fresh water bottle and Turn option
As the owner of the treatment center, you are generally responsible for
the water quality.
The bacterial count must comply with the national regulations for drinking
water and must not exceed 500 CFU/ml under any circumstances (CFU:
colony forming unit).
If the bacterial count is too high, the building water system must be
checked and the cause of contamination eliminated. Alternatively, a self-
sufficient water supply can also be installed. In addition, with the INTEGO
an optional fresh water bottle, or with the INTEGO pro the empty
disinfectant tank can be used as a water container. For treatment centers
with the Ambidextrous option, depending on the equipment, the fresh
water bottle or the empty disinfectant tank can be used as a water
container.
Before installation of the treatment center, an acceptable microbiological
water quality for the domestic water supply must be ensured and
documented in the form of the bacterial count. Sampling and the bacterial
count must be performed by a competent laboratory.
Test the water quality from the treatment center at regular intervals and
after it has not been used for > 1 week, see Microbiological water test
[ 205]. Please contact your specialized dealer or your relevant dental
association for the respective national requirements and measures.
Further information on the media quality requirements are listed in the
"Installation conditions" document.
Treatment water, immunosuppressed patients, with sterile solution
2.6
Connection to the public drinking water system
Disinfection system, optional or with fresh wate r bottle
Treatment center isolated from the public drinking water supply
The INTEGO pro treatment center, if it is equipped with a disinfection
system, complies with the requirements of EN 1717 (free discharge with
an isolation distance 20 mm) and the DVGW German Gas and Water
Association). It is intrinsically safe according to the W540 worksheet and
WARNING
Highly immunosuppressed patients or patients with specific pulmonary
diseases should not come in contact with the water of the treatment unit.
The use of sterile solutions is recommended.