5. Delivery, returns, and storage
45
5.5 
with lubricant
The conditions mentioned in the follow-
ing will have to be adhered to when storing
products filled with lubricant,
5.5.1 Storage period of up to 6 months
The filled products can be used without hav-
ing to take further measures
.
5.5.2 Storage period from 6 to 18
months
Lubrication pump
Connect the lubrication pump electrically
Switch the lubrication pump on and let it
run, e.g. by triggering an additional lubri-
cation, until about 4 cm³ of lubricant will
leak from each pump element
Disconnect the lubrication pump from the
power supply
Remove and dispose of leaked lubricant
Metering device
Remove all lubrication lines and closure
screws, if any
Connect the lubrication pump primed
with new lubrication grease suitable for
the application purpose to the metering
device
Let the lubrication pump run until new
lubricant leaks from the outlets of the
metering device/lubrication lines
Remove leaked lubricant
IReinstall closure screws where applicable
Feed lines
Dismantle preassembled lubrication lines
Ensure that both lubrication line ends
remain open
Prime lubrication lines with new lubricant
5.5.3 Storage period exceeding 18
months
To avoid dysfunctions consult the manufac-
turer before commissioning. The general
procedure to remove the old grease filling
corresponds to that of a storage period from
6 to 18 months.
- 51 -
951-171-049
Version 02

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SKF SSV Series and is the answer not in the manual?

SKF SSV Series Specifications

General IconGeneral
BrandSKF
ModelSSV Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals