11. Troubleshooting
11. Troubleshooting
Fig. 26 Fault table 1
In addition to the indications regarding troubleshooting stated here, observe all indications regarding troubleshooting stated in the lubrication
pump instructions. To check the individual outlets you may have to run the lubrication pump for a longer period of time as the single outlets are
provided with lubricant one after the other and thus there may be required several cycles of the upstream metering device. If the fault cannot be
determined and remedied, contact our Customer Service.
Fault Possible cause Remedy
Poor or excessive lubrication of all lube
points
Wrong setting of lubrication time or pause
time on the lubrication pump
Check and, if necessary, correct lubrication and pause times
Poor or excessive lubrication of individual
lubrication points
Wrong output setting on the metering
device
Check the output settings for compliance with the specifi-
cations. If needed, correct the output settings.
Poor lubrication of individual lubrication
points
Wrong output setting on the metering
device
No check valve mounted to the metering
device outlet
Check and, if necessary, mount check valve or replace de-
fective check valve.
Check the output settings for compliance with the specifi-
cations. If needed, correct the output settings.
- 62 -
951-171-049
Version 02

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SKF SSV Series and is the answer not in the manual?

SKF SSV Series Specifications

General IconGeneral
BrandSKF
ModelSSV Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals