6. Installation
6
- 55 -
951-171-049
Version 02
6.4.3 SSVD, SSVD-E and SSVDL
metering devices
The output of the SSV, SSVD-E and SSVDL
metering devices can be adapted by using
different metering screws. An additional
adaptation is possible by closing unneeded
outlets with closure screws in case of SSVD
and SSVD-E or by using connection bars in
case of SSVDL metering devices
To change the output with metering screws
proceed as follows:
• Remove protective caps from the meter-
ing device
• Screw the required metering screw into
the corresponding outlet
• Repeat the procedure for all other
outlets.
Tightening torques, see corresponding table
in these instructions.
Fig. 21 Metering screws
180 140 100
80
60
840 142030
1.80 1.40 1.00 0.80 0.60 0.40 0.30 0.20 0.14 0.08 cm
3
J I H G F E D C B A
cm
3