5.6-5 Motor Controller Thermal Sensor
If the controller temperature exceeds 85°C (185°F), the maximum current is reduced in proportion to the
thermal increase. The temperature can never exceed 105°C (221°F).
Maximum current = 100%
Maximum current = 75%
Maximum current = 50%
85°C 90°C 95°C 105°C
T(°C)
Imax
Ambient
Temperature
Resistance (ohm)
°C
°F
Min Typ Max
-40 -40 340 359 379
-30 -22 370 391 411
-20 -4 403 424 446
-10 14 437 460 483
0 32 474 498 522
10 50 514 538 563
20 68 555 581 607
25 77 577 603 629
30 86 599 626 652
40 104 645 672 700
50 122 694 722 750
60 140 744 773 801
70 158 797 826 855
80 176 852 882 912
90 194 910 940 970
100 212 970 1000 1030
110 230 1029 1062 1096
120 248 1089 1127 1164
130 266 1152 1194 1235
140 284 1216 1262 1309
150 302 1282 1334 1385

Table of Contents