-44-
No.PF※※-OMW0007-A
[F14] Zero cut-off setting
Forced display of zero to remove flickering at the lower limit during measurement.
<Operation>
Press the UP or DOWN
button in function selection mode to display [F14].
Press the SET button. Move on to the setting of the zero cut-off function.
Press the SET button to set. Move on to checking the zero cut-off set value.
During the checking of the Zero cut-off set value
Press the UP and DOWN button simultaneously for 1 second or longer for resetting the set
value (to the default value).
Press the SET button to set. Return to function selection mode.
[F14] Zero cut-off setting completed
Setting of zero cut-off function
Press the UP or DOWN button to select the zero
cut-off function.
Check the zero cut-off set value
The set zero cut-off range is displayed in
percent (%).