Servodrives / inverters series COSMOS 301X Installation, use and maintenance manual - EN
The wiring must be made by a shielded cable; the shield on the cable end on the servo-drive side must be
soldered directly to the connector shell. Connect the other end of the shield to the encoder housing, when
possible.
Since differential signals are involved, each pair of signals (such as U+ and U-) must be carried with a
twisted pair. As to the power conductors, they must be properly sized, in order to prevent excessive voltage
drops; conductors with a larger cross-section may be necessary when the wiring extends over great
distances. Consult the technical documentation supplied by the manufacturer of the encoder for further
details.