13) UPS Lamp - Shows the status of the battery backup device (A530 & A320 only).
During normal operation this lamp is always on. If the incoming power to the shop goes
off, this lamp will be on for as long as the battery backup lasts, which is about 15
Minutes. If the power in the shop returns within 15 Minutes, the machine will reboot and
continue executing the program. CAUTION: If the control is at an M00 and the power
goes off and back on within 15 minutes the machine may continue onto the next line after
the M00.
14) Alarm Lamps - These lamps, if on, would indicate that a fuse has blown in the power
supply. Do not attempt to continue cutting. Please call the service dept. for exact location
of the fuse, as this is different for each machine model
15) Submerged lamp - This LED shows the status of the worktank float switch. On
indicates that the worktank is filled up to the floats.