Communication Status
Thisscreendisplaysthestatusofconnectionoption(s):LAN,RS485,cellularorZigBeePlug-in.
Communication
LAN
Connected
RS485-1
SE Slave
NC
RS485-2
Modbus
2 of 2
Cellular
N/A
ZigBee
NC
Foreachcommunicationoption,oneofthefollowingstatusesisdisplayed:
l Connected:Theinverterestablishedasuccessfulconnectionandcommunicationwiththespecified
serverport
l NC:NotConnected.RefertoTroubleshootingCommunicationonpage73
l S_OK:Theconnectiontothemonitoringplatformissuccessful(shouldappearonlyiftheinverteris
connectedtotheserver)
l N/A:NotApplicable
l x of y:Numberofdevicesconnectedoutofalldevices
l
Temporarilydisplayed(witha clocksign):
o
Initializing communication
o
Connectingtoanetwork
o
ConnectingtoSolarEdgeservers
l
Error message(withthe sign).RefertoTroubleshootingCommunicationonpage73.
Chapter 5: Activating, Commissioning and Configuring the System Using the Inverter
-Three Phase Inverter with Synergy Technology Installation MAN-01-00402-1.4