EasyManua.ls Logo

SolarEdge SE66.6KUS - Step 1: Mounting and Grounding the Power Optimizers

SolarEdge SE66.6KUS
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
o
Donotuseextensioncablesbetweenamoduleandapoweroptimiser,betweentwomodules
connectedtothesameoptimiser,orbetweentwooptimisersotherthaninthecasesspecified
below.
o
Youcanuseextensioncablesbetweenpoweroptimisersonlyfromrowtorow,aroundobstacles
withinarow,andfromtheendofthestringtotheinverter,aslongasthemaximumdistanceis
notexceeded.
l Theminimumandmaximumstringlengthguidelinesarestatedinthepoweroptimiserdatasheets.
RefertotheDesignerforstringlengthverification.TheDesignerisavailableontheSolarEdgewebsite
athttps://www.solaredge.com/us/products/installer-tools/designer#/.
l Completelyshadedmodulesmaycausetheirpoweroptimiserstotemporarilyshutdown.Thiswill
notaffecttheperformanceoftheotherpoweroptimisersinthestring,aslongastheminimum
numberofunshadedpoweroptimisersconnectedinastringofmodulesismet.Ifundertypical
conditionsfewerthantheminimumoptimisersareconnectedtounshadedmodules,addmore
optimiserstothestring.
l Equipmentgroundingtighteningtorques:4-6AWG:45lb-in,8AWG:40lb-in,10-14AWG:35lb-in.
l Toallowforheatdissipation,maintaina2.5cm/1"clearancedistancebetweenthepoweroptimiser
andothersurfaces,onallsidesexceptthemountingbracketside.
Figure 4: Power optimiser clearance
l Wheninstallingmodulesinaconfinedspace,forexample,ifinstallingBuilding-integratedphotovoltaic
(BIPV)modules,ventilationmeasuresmaybeneededtoensurethepoweroptimisersarenotbe
exposedtotemperaturesoutsidetheirspecifications.
NOTE
The images contained herein are for illustrative purposes only and may vary depending on product
models.
Step 1: Mounting and Grounding the Power
Optimizers
Foreachofthepoweroptimisers
1
:
1
Not applicable to smart modules.
-Three Phase Inverter with Synergy Technology Installation MAN-01-00402-1.4
16
Step 1: Mounting and Grounding the Power Optimizers

Table of Contents

Related product manuals