NOTE
If using a cable longer than 10 m / 33 ft in areas where there is a risk of induced
voltage surges by lightning, it is recommend to use external surge protection
devices.
For details refer to: http://www.solaredge.com/files/pdfs/lightning_surge_
protection.pdfhttp://www.solaredge.us/files/pdfs/lightning_surge_protection.pdf.
Figure 37: Example of Ethernet connection
To connect the Ethernet cable:
1. Openthecommunicationgland.
CAUTION!
The gland includes a rubber waterproof fitting, which should be used to ensure proper sealing.
Le cote interne du gland contient une rondelle qui doit être utilisée pour une bonne étancheïté.
2. RemovetherubberfittingfromtheglandandinserttheCAT5/6cablethroughtheglandandthrough
theglandopeningintheConnectionUnit.
3. Removetheplasticsealfromthelargeopeningthathasacutintherubberfitting.
-Three Phase Inverter with Synergy Technology Installation MAN-01-00402-1.4
62