To connect the RS485 communication bus:
1.
Openthecommunicationgland.
CAUTION!
The gland includes a rubber waterproof fitting, which should be used to ensure proper sealing.
Le cote interne du gland contient une rondelle qui doit être utilisée pour une bonne étancheïté.
2.
RemovetherubberfittingfromtheglandandinserttheCAT5/6cablethroughtheglandandthrough
theglandopeningintheConnectionUnit.
Figure 42: Inserting communication cables
3. Removethesealfromoneoftheopeningsinthecommunicationglandandinsertthewirethrough
theopening.
4.
Pulloutboth3-pinRS485terminalblocks,asshownbelow:
Figure 43: RS485 connectors and termination switch
-Three Phase Inverter with Synergy Technology Installation MAN-01-00402-1.4